D-Tools Certified Product
This product can be found in the D-Tools manufacturer product database and specified as a third party device when building and proposing a system using D-Tools System Integrator software. D-Tools data includes attributes that make it easier to sell, design, and install systems including: overview, specifications, images, product documentation and more. AMX is a member of the D-Tools Manufacturer Vantage Point (MVP) program designed to provide D-Tools customers the most up-to-date product information.
COUNTRY OF ORIGIN: MEXICO
To satisfy the requirements/regulations of existing or future government programs, this two-letter code is being provided to designate the country of origin for this product.
(Click here for a list of all countries and their respective two-letter code.)
NetLinx Control Cards and NetModules
PDF | 500 KB
Operation/Reference Guide - NetLinx CardFrame, Control Cards and NetModules
PDF | 632 KB
Installation Guide - NXC-VAI4 Voltage Output/Analog Input Card
PDF | 168 KB
| Rev. D

NXC-VAI4 Firmware
KIT | 85.1 KB
| v 1.0.04
NXC-VAI4
PNG | 4.55 MB
OVERVIEW
The NXC-VAI4 Analog Voltage Card is equipped with four
independent analog-to-digital inputs and four independent
digital-to-analog outputs, which are controllable over the ICSP
network. Each port can be configured for a variety of DC input
and output signals. NetLinx Control Cards provide flexible,
modular building blocks for creating advanced
control applications.
FEATURES
SPECIFICATIONS
POWER
INPUTS
OUTPUTS
D/A - A/D CONVERSION
AVAILABLE INPUT VOLTAGES
AVAILABLE OUTPUT VOLTAGES
330 mA @ 12 VDC
Four high-impedance analog DC inputs
Four analog DC outputs (user-configurable)
A/D and D/A converters for analog sampling and control. 8 or 10-bit; userselectable
via the ADMODE Send_Command
0 V to +12 V
- Maximum output current = 60 mA
- Over-voltage protection to +28 VDC
- Maximum external reference input voltage = +12 VDC
- Over-voltage protection to +28 VDC
- +5 V reference output, maximum current = 60 mA
- This output is intended to drive a ground-referenced load
| NAME | DESCRIPTION | PART # |
|---|---|---|
| NXF | NetLinx CardFrame | (FG2001) |
| NXS-NMS | NetModule Shell | (FG2009-10) |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
|||
|